Getting Started

Rear I/O Terminals

Rear Panel Terminals

Terminal

Remarks

[ALARM IN]

Memo :

● Set the impedance at the output end to 10 kK or lower.

Make Contact Input

[EMERGENCY]
[ALARM RESET]

Memo :

● Set the impedance at the output end to 10 kK or lower.

Make Contact Input

[EXT REC IN]

Memo :

● Set the impedance at the output end to 10 kK or lower.

Make Contact Input

[OPE ON/OFF]

Memo :

● Set the impedance at the output end to 10 kK or lower.

Make Contact Input

[REC TALLY]
[ALARM OUT]
[WARNING OUT]
[OPTION OUT1]
[OPTION OUT2]

(External Pull-up Level)
The make contact is formed using the individual output terminals and the COM terminal.
Turning off the power of this unit switches the output of the output terminals to break.

Auto Collector Output
(DC15V, 10 mA and
below)

250 ms and
above

250 ms and
above

Make

Break

ⅷ Name of Input Event

Alarm IN 1 to 8 Rising (VR-N1600U/E)
Alarm IN 1 to 4 Rising (VR-N900U)

ⅷ Name of Input Event

Alarm IN 1 to 8 Falling (VR-N1600U/E)
Alarm IN 1 to 4 Falling (VR-N900U)

250 ms and
above

250 ms and
above

1 s and above

Approx.
50 ms

OPE ON

OPE OFF

Make Output

ⅷ Name of Output Event

Set output Option Out 1,2 high

ⅷ Name of Output Event

Set output Option Out 1,2 low