background image

9

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

(2) Outdoor unit C1251 / CL1251

Control PCB

Part No.

— / POW-CL1251

Controls

Microprocessor

Control circuit fuse

115V 5A

Compressor

Type

Rotary (Hermetic)

Compressor model

C-R91H2G

Nominal output

W

900

Compressor oil … Amount

cc

SUNISO 4GSD-T … 470

Coil resistance (ambient temp. 68°F (20°C))

½

C – R: 0.576

C – S: 2.261

Safety devices

Type

External (OLR)

Overload relay

MRA98693-9200

Run capacitor

µF

40

VAC

400

Crank case heater

— / 115V, 20W

Heat Exchanger Coil

Coil

Aluminum plate fin / Copper tube

Rows

1

Fin pitch

inch (mm)

1/16 (1.4)

Face area

ft

2

(m

2

)

3.27 (0.304)

External Finish

Acrylic baked-on enamel finish

Fan & Fan Motor

C1251

CL1251

Type

Propeller

Q’ty … Dia. and length

inch. (mm)

1 … 16-17/32 (ш 420)

1 … 16-17/32 (ш 420)

Fan motor model … Q’ty

UE6-21BA1P … 1

UE6T-21J1P … 1

No. of poles … rpm (115V, High)

6 … 630

6 … 630

Nominal output

W

20

20

Coil resistance (ambient temp. 68°F (20°C))

½

BLU – BRN: 45.3

BLU – BRN: 45.3

BLU – PNK: 50.5

BLU – PNK: 50.5

Run capacitor

µF

8

8

VAC

440

440

099-464 SM (1-16) 2/7/00 4:09 PM Page 9