3-2. outdoor unit – Sanyo CL1852 User Manual

Page 15

Advertising
background image

12

Transformer (TR)

Rating

Primary

Secondary S1

S2

S3

Capacity

Coil resistance

½

(at 70°F (21°C))

Thermal cut-off temp.

Thermistor 1 (Air temp.)

DTNTKS132B

Resistance

k

½

32°F (0°C) 15 ± 2%

PTC Thermistor

PS2A E20-470

Resistance

½

(at 77°F (25°C))

47 ± 25%

2-3-2. Outdoor Unit

(1) Outdoor unit C0951 / CL0951

Power Relay (PR)

Coil rating

Coil resistance

½

(at 68°F (20°C))

Contact rating

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Transformer (TR)

— / ATR-T4

Rating

Primary

— / AC 115V, 60Hz

Secondary

— / DC 19V, 0.5A

Capacity

— / 5VA

Thermistor (Air temp.)

— / DTNTKS132B

Resistance

k

½

32°F (0°C) 15 ± 2%

PTC Thermistor

PS2A E20-470

Resistance

½

(at 77°F (25°C))

47 ± 25%

(2) Outdoor unit C1251 / CL1251

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Transformer (TR)

— / ATR-T5

Rating

Primary

AC 115V, 60Hz

Secondary S1

— / DC 19V, 0.5A

Capacity

5VA

Thermistor (Air temp.)

— / DTNTKS132B

Resistance

k

½

32°F (0°C) 15 ± 2%

(3) Outdoor unit C1852 / CL1852

Power Relay (PR)

HH62S

Coil rating

DC 24V

Coil resistance

½

(at 68°F (20°C))

650 ± 10%

Contact rating

AC 250V, 20A

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

099-464 SM (1-16) 2/7/00 4:09 PM Page 12

Advertising