Specifications, 1. unit specifications – Sanyo CL1852 User Manual

Page 5

Advertising
background image

2

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

Remarks: Rating conditions are

Cooling: Indoor air temperature

80°F D.B. / 67°F W.B.

Outdoor air temperature 95°F D.B. / 75°F W.B.

2. SPECIFICATIONS

2-1. Unit Specifications

(1) Indoor unit

KS0951

Outdoor unit C0951 / CL0951

Performance

Cooling

Capacity

kW

2.64

9,000

Air circulation (High)

ft

3

/min

270 (7.65)

Moisture removal (High)

Pints/h

2.2

Electrical Rating

Cooling

Available voltage range

V

104 – 126

Running amperes

A

8.8

Power input

W

900

Power factor

%

89

SEER

BTU/W

10.0

Compressor locked rotor amperes

A

49

Features

Controls / Temperature control

Microprocessor / I.C. thermostat

Control unit

Wireless remote control unit

Timer

ON / OFF 12 hours, 1-hour OFF

Fan speeds

Indoor / Outdoor

3 and Auto / 1 (Hi)

Airflow direction (Indoor)

Horizontal

Manual

Vertical

Auto

Air filter

Washable

Compressor

Rotary (Hermetic)

Refrigerant / Amount charged at shipment

lb. (kg)

1.28 (0.58)

Refrigerant control

Capillary tube

Operation sound

Indoor: Hi / Me / Lo

dB-A

38 / 34 / 32

Outdoor: Hi

dB-A

48

Refrigerant tubing connections

Flare

Max allowable tubing length at shipment

ft. (m)

25 (7.5)

Refrigerant tubing

Narrow tube

inch (mm)

1/4 (6.35)

diameter

Wide tube

inch (mm)

3/8 (9.52)

Cooling

Voltage Rating

115V

Dimensions & Weight

Indoor Unit

Outdoor Unit

Unit dimensions

Height

inch (mm)

10-5/8 (270)

21-1/4 (540)

Width

inch (mm)

31-11/16 (805)

31-1/2 (800)

Depth

inch (mm)

6-31/32 (177)

11-13/32 (290)

Package dimensions

Height

inch (mm)

9-13/16 (249)

23-31/32 (609)

Width

inch (mm)

33-21/32 (855)

38-5/8 (981)

Depth

inch (mm)

13-5/16 (338)

16-3/16 (411)

Weight

Net

lb. (kg)

17.6 (8.0)

66.1 (30)

Shipping

lb. (kg)

22.0 (10.0)

75.0 (34)

Shipping volume

cu.ft (m

3

)

2.51 (0.071)

8.67 (0.246)

099-464 SM (1-16) 2/7/00 4:09 PM Page 2

Advertising