3. some part of air conditioner does not operate – Sanyo CL1852 User Manual

Page 52

Advertising
background image

49

9-3. Some Part of Air Conditioner Does Not Operate

9-3-1. Only indoor fan does not run

9-3-2. Only outdoor fan does not run

Fan cannot
be turned.

Check fan casing
for foreign matter
on inside.

Check fan rotation.
Turn fan gently once or twice
by hand.

•

Measure resistance of indoor fan
motor winding.

•

OK

•

Fan motor burnout
or foreign matter
in bearings.

Repair or replace.

Remove foreign
matter or repair.

Check fan motor capacitor.

•

Fan cannot
be turned.

Check fan casing
for foreign matter
on inside.

Check fan rotation.
Turn fan gently once or twice
by hand.

•

Measure resistance of outdoor fan
motor winding.

•

OK

•

Fan motor burnout
or foreign matter
in bearings.

Repair or replace.

Remove foreign
matter or repair.

Check fan motor capacitor.

•

099-464 SM (17-56) 2/7/00 4:19 PM Page 49

Advertising