54

10-2. Checking Continuity of Fuse

on PCB Ass’y

Remove the PCB Ass’y from the electrical compo-

nent box. Then pull out the fuse from the PCB

Ass’y. (Fig. 5)

Check for continuity using a multimeter as shown in

Fig. 6.

10-3. Checking Motor Capacitor

Remove the lead wires from the capacitor terminals,

and then place a probe on the capacitor terminals as

shown in Fig. 7. Observe the deflection of the pointer,

setting the resistance measuring range of the multime-

ter to the maximum value.

The capacitor is “good” if the pointer bounces to a

great extent and then gradually returns to its original

position.

The range of deflection and deflection time differ

according to the capacity of the capacitor.

Fuse

PCB Ass’y

Fig. 5

Fuse

Fig. 6

Multimeter

Compressor motor
capacitor

Fan motor
capacitor

Fig. 7