Sierra Raven EDGE User Manual

Page 102

Advertising
background image

Configuration Commands

Rev 3.0B Feb.08

98

*IPPINGADDR=[d.d.d.d][name]

Set the IP address or valid internet domain name for the Raven 
to ping to keep itself alive (online). *IPPING must to be set to a 
value other than 0 to enable pinging. 

d.d.d.d=IP address

name=domain name

*MSCIUPDADDR=name[/port]

Modem Status Update Address ‐ where Name/Port is the 
domain name and port of the machine where the modem 
status updates will be sent. The status parameters of the Raven 
are sent in an XML format.

name=domain name

port=port

*MSCIUPDPERIOD=n

Modem Status Update Period ‐ where n defines the update 
period in seconds.

n=0 : Disabled. 

n=1‐255 seconds

*NETWDOG=n

Network connection watchdog: The number of minutes to wait 
for a network connection. If no connection is established 
within the set number of minutes, the Raven modem resets. 

n=0 : Disabled.

n=minutes : Default = 120 min.

*RESETCFG

Wipe the non‐volatile data in the modem. Cannot be used with 
AceManager.

Caution: You may need to reactivate your modem if you erase the
non-volatile data.

*SNMPCOMMUNITY=string

The SNMP Community String acts like a password to limit 
access to the modem’s SNMP data.

string =string of no more than 20 characters (default = 
public).

*SNMPPORT=n

This controls which port the SNMP Agent listens on.

Advertising