n=0 : SNMP is disabled. 

n=1‐65535

*SNMPSECLVL=n

Selects the security level requirements for SNMP communica‐
tions. 

n=0 : No security required. SNMPv2c and SNMPv3 
communications are allowed.

n=1 : Authentication equivalent to “authNoPriv” setting in 
SNMPv3. SNMPv3 is required to do authentication, 
SNMPv2c transmissions will be silently discarded.

n=2 : Authentication and encryption, equivalent to 
“authPriv”ʹ setting in SNMPv3. SNMPv3 is required to do 
authentication and encryption, SNMPv2c and SNMPv3 
authNoPriv transmissions will be silently discarded. 
Messages are both authenticated and encrypted to prevent 
a hacker from viewing its contents.

*SNMPTRAPDEST=host/[port]

Controls destination for SNMP Trap messages. If port is 0 or 
host is empty, traps are disabled. Traps are sent out according 
to the SNMP security level (i.e. if the security level is 2, traps 
will be authenticated and encrypted). Currently, the only trap 
that can be generated is linkup.

host=IP address

port=TCP port

*SNTP=n

Enables daily SNTP update of the system time. 

n=0 : Off 

n=1 : On

*SNTPADDR=[d.d.d.d][name]

SNTP Server IP address, or fully‐qualified domain name, to 
use if *SNTP=1. If blank, time.nist.gov is used.

d.d.d.d=IP address

name=domain name

*TELNETTIMEOUT=n

Telnet port inactivity time out. By default, this value is set to 
close the AT telnet connection if no data is received for 2 
minutes.

n=minutes