Ppp/ethernet, Ipmgrupdaten=m *modemname=name – Sierra Raven EDGE User Manual

Page 94

Advertising
background image

Configuration Commands

Rev 3.0B Feb.08

90

n=2 : Second IP Manager server. 

key=128‐bit key in hexadecimal [32 hex characters]

*IPMGRUPDATEn=m

Sets the number of minutes to periodically send an IP update 
notification to the corresponding server. This will occur even if 
the IP address of the Raven doesnʹt change. *IPMGRUPDATE1 
is used to set the refresh rate to *IPMANAGER1, while 
*IPMGRUPDATE2 is used with *IPMANAGER2. If the value is 
set to 0, then periodic updates will not be issued (i.e. IP change 
notifications will only be sent when the IP actually changes). 

n=1 : First IP Manager server. 

n=2 : Second IP Manager server. 

m=0, 5‐255 : Number of minutes to send an update.

*MODEMNAME=name

Name of the Raven (up to 20 characters long) to use when 
performing IP address change notifications to IP Manager. The 
value in *DOMAIN provides the domain zone to add to this 
name. 

name=modem name (for example, mymodem) 

Example: if *MODEMNAME=mymodem and 
*DOMAIN=eairlink.com, then the modemʹs fully qualified 
domain name is mymodem.eairlink.com. 

Automatically Generated Names: 

#I3 ‐ The ESN/IMEI will be used as the name. 

#CCID ‐ The CCID will be used as the name. 

#NETPHONE ‐ The phone number will be used as the name.

Tip: Each modem using IP Manager needs a unique name. Two
modems cannot be called “mymodem”. One could be “mymodem1”
with the other as “mymodem”.

PPP/Ethernet

This group includes commands specific to PPP (serial) or 
Ethernet connections between the Raven and a connected 
device.

Advertising