Error message list – Sony HDW-1800 User Manual

Page 103

Advertising
background image

103

10-3 Error Messages

Cha

p

te

r 10 Maint

ena

nc
e and

In

s

p

e

c

tion

Error Message List

Code

Message

Description

(ALARM indicator
flashing)

Abnormal interface between the lower control panel (on KY-615 board) and SYS CPU (on
SS-340 and SS-101 boards) has been detected on the lower control panel.

01

REEL TROUBLE

Tape slacking has been detected in the threading or unthreading operation.

02

REEL TROUBLE

Tape slacking or tape breaking has been detected in search, fast forward,or rewind mode.

03

REEL TROUBLE

Tape slacking, tape breaking,or supply or take-up reel locking has been detected in recording
or playback mode.

04

REEL TROUBLE

Abnormal tape transport speed has been detected in fast forward or rewind mode.

05

REEL TROUBLE

Malfunction of the supply or take-up reel has been detected during cassette insertion.

06

TAPE TENSION

Excessive tape tension has been detected in recording or playback mode.

07

CAPSTAN TROUBLE

Malfunction of capstan motor has been detected.

08

DRUM TROUBLE

Malfunction of drum motor has been detected.

09

TH/UNTH MOTOR

Malfunction of threading or unthreading operation has been detected.

0A

THREADING

The tape top processing has not been completed in the threading mode.

10

HUMID

Moisture condensation has been detected.

11

TAPE T/E SENSOR

The tape top and tape end have been detected simultaneously.

12

TAPE TOP SENSOR

Malfunction of tape top sensor has been detected.

13

TAPE END SENSOR

Malfunction of tape end sensor has been detected.

14

FAN MOTOR

Malfunction of cooling fan motor has been detected.

20

CASS COMP MOTOR

Malfunction of cassette compartment up or down operation has been detected.

21

REEL SFT MOTOR

Malfunction of movement of the reel table corresponding to the cassette size has been
detected.

22

REEL POS SENSOR

The L-cassette and S-cassette positions of the reel table have been detected simultaneously.

23

THRED RING SENS

The thread end and unthread end states of the threading ring have been detected
simultaneously.

92

INTERNAL I/F1

Abnormal interface between SYS CPU (on SS-101 board) and other CPU/MPU has been
detected.

93

CPU INITIALIZE
ERROR

Abnormal interface between SV CPU (on SS-101 board) and DRUM CPU (on DR-508 board)
has been detected.

95

OTHERS NV-RAM
ERROR

Abnormal operation has been detected on NV-RAM on FP-153 board.

96

SY NV-RAM ERROR

Abnormal operation has been detected on NV-RAM (on SS-101 board) for the system
control.

97

SV NV-RAM

Abnormal operation has been detected on NV-RAM (on DR-508 board) for the servo system.

98

RF NV-RAM ERROR

Abnormal operation has been detected on NV-RAM (on EQ-104 board) for the RF system.

99

INTERNAL I/F 2

Abnormal interface between SYS CPU (on SS-101 board) and SERVO CPU (on SS-101
board) or among each board (EQ-104, HPR-21, VPR-98, APR-80, SY-340 or KY-615 board)
has been detected.

Advertising