P02: tc – Sony HDW-1800 User Manual

Page 65

Advertising
background image

65

8-2 Function Menu Item List

Ch
apt

er 8

F

u

nc
tio
n

Men

u

a) CONFI playback is disabled during editing.
b) The selection of LTC or VITC depends on the setting of F10 (TCR) in

function menu page P02: TC.

c) Setting screen is not displayed when F1 (TCG SRC) is set to

“INTERNAL” and F2 (TCG MODE) is set to “PRESET” in function
menu page P02: TC.

P02: TC

This is a function menu page for setting items relating to
timecode.

F8
(COUNTER)

Select the time data to display in time data
display

(see page 17).

TC: Playback timecode read by the internal

timecode reader, or recording
timecode. The LTC or VITC time data
type indicator

(see page 18) lights.

b)

UB: User bits data of playback timecode or

recording timecode. The LUB or VIUB
time data type indicator lights,
depending on whether the timecode is
LTC or VITC.

b)

CTL: The running time of the tape being

played back or recorded, as calculated
from a count of CTL signals recorded
on the tape. The time is displayed in
Hours:Minutes:Seconds:Frames
format.

F9 (MENU)

Puts the system into setup menu mode

(see Chapter 9). (Jump to P108: SETUP
(TOP))
When the current setup menu settings are
the same as the contents of any of menu
banks 1 to 4, or the factory defaults,the
corresponding indication (BANK1),
(BANK2), (BANK3), (BANK4) or (DEFLT)
appears below the time data display on the
LCD.

F10 (TCG
SET)

• When F8 (COUNTER) is set to “TC”, a

screen appears that allows you to set the
initial value of the timecode generated by
the internal timecode generator

(see

page 17).

c)

• When F8 (COUNTER) is set to “UB”, a

screen appears that allows you to set the
timecode user bits

(see page 17).

c)

Item

Setting

Item

Setting

F1 (TCG SRC) Select the signal source of the timecode

with which the internal timecode generator
synchronizes.
INTERNAL: Synchronizes according to the

initial preset value set by control panel
operation or by control from the device
connected to the REMOTE1-IN (9P)
connector, or synchronize with the
timecode of the playback tape.

EXT LTC: Synchronizes with the external

timecode signal input to the TIME
CODE IN connector.

SDI IN: Synchronizes with the timecode

data superimposed on the HDSDI
signal input to the HDSDI INPUT
connector.

F2
(TCG MODE)

Select one of the following for timecode
regenerated by the internal timecode
generator.
PRESET: Presets the initial value of

timecode generated by the internal
timecode generator, as specified by
control panel operation or by control
from the device connected to the
REMOTE1-IN (9P) connector. This
operation is enabled when F1 (TCG
SRC) is set to “INTERNAL”.

RGN: LTC: Regenerates by synchronizing

with the LTC timecode value read by
the internal timecode reader.

RGN: VITC: Regenerates by synchronizing

with the VITC timecode value read by
the internal timecode reader.

F3 (TCG RUN) Select one of the following running modes

for the internal timecode generator.
FREE: Timecode continues to increase as

long as the unit is powered on,
regardless of the unit’s operating
mode.

REC: Timecode increases during recording

only.

If you select this mode, you should also set
F1 (TCG SRC) to “INTERNAL”, and set F2
(TCG MODE) to “PRESET” in this menu
page.

F4 (DROP
FRM)

In 59.94i, 29.97PsF mode, select drop-
frame or non-drop-frame mode for the
timecode generator and the CTL counter.
DF: Drop-frame mode
NDF: Non-drop-frame mode

F5

(No function assigned)

F6

(No function assigned)

F7

(No function assigned)

F8

(No function assigned)

F9

(No function assigned)

Advertising