10-4 Moisture Condensation / 10-5 Regular Checks

Chap

te

r 10

Ma

int
ena

nc
e and I

n

s

pec

tion

10-4 Moisture
Condensation

When the unit is suddenly moved from a cold to a warm
location, or used in a very humid place, moisture from the
air can condense on the head-drum. This is called moisture
condensation. If the tape is run in this state, it can adhere
to the drum and damage the tape. To prevent this, the unit
is provided with a moisture detecting function.
If moisture condenses on the head-drum while the unit is
in use, the ALARM indicator lights and “ERR-10” is
displayed in the time data display.

If this happens, the drum and capstan motors stop and the
cassette is automatically ejected. Then, the drum starts to
rotate again to dry its surface. In this state, the unit is not
operable. When the moisture has evaporated, the error
message disappears and the ALARM indicator goes off.

If “ERR-10” appears and the ALARM
indicator lights immediately after powering
the unit on

Leave the unit powered on and wait until the error message
disappears and the ALARM indicator goes off.
While the indicator is lit, you cannot insert a cassette.
When the indicator goes off and the error message
disappears, you can use the unit.

If you move the unit from a cold to a warm
location

Leave the unit powered off for about 10 minutes, since it
takes some time to detect moisture condensation in this
state.

10-5 Regular Checks

10-5-1 Digital Hours Meter

The digital hours meter in the time data display can display
seven items of information about the operational history of
the unit in each corresponding mode. Use it as a guide in
scheduling periodic maintenance.

Display modes of the hours meter

H01: OPERATION mode
Displays the total number of hours the unit has been
powered on in units of 1 hour.

H02: DRUM RUNNING mode
Displays the total number of hours the drum has run with
tape threaded in units of 1 hour.

H03: TAPE RUNNING mode
Displays the total number of hours the unit has been in fast
forward, rewind, playback, search, recording or editing
(except for stop and still) mode in units of 1 hour.

H04: THREADING mode
Displays the total number of times tape has been threaded
in the unit.

H12: DRUM RUNNING mode (resettable)
Same as H02 except that the count is resettable.
This can be used as a guide in determining when to replace
the drum.

H13: TAPE RUNNING mode (resettable)
Same as H03 except that the count is resettable.
This can be used as a guide in determining when to replace
components such as fixed heads and pinch rollers.

H14: THREADING mode (resettable)
Same as H04 except that the count is resettable.
This can be used as a guide in determining when to replace
components such as the threading motor.

R- 10

ER

ALARM indicator

“ERR-10” appears in the time data display.