Appendix – Sanyo PLC HF10000L User Manual

Page 98

Advertising
background image

9

Appendix

Status Read Commands

The command is sent from PC to the projector with

the format below;

“CR” [Command] [CR]

Command: one character (refer to the command

table below.)

The projector decodes the command and returns the

'Character string' with the format below;

Format

Command

Function

Return

value

Projector status

CR0

Status Read

00

Power On

80

Stand-by mode

40

Countdown

20

Cooling down

10

Power Malfunction

28

Cooling down at the temperature anomaly

24

Cooling down at Power Management mode

04

Power Management mode after Cooling down

21

Cooling down after the projector is turned off when the lamps
are out.

81

Stand-by mode after Cooling down when the lamps are out.

88

Stand-by mode after Cooling down at the temperature
anomaly.

2C

Cooling down when the projector is turned off by the shutter
management function.

8C

Stand-by mode after Cooling down by the shutter
management function.

CR6

Temperature Read

%1 %2

%1 = Temperature at Sensor 1 (˚C)
%2 = Temperature at Sensor 2 (˚C)
(ex.) %1 = 12.3 (˚C), %2 = 23.4 (˚C)
--> The projector returns “ 12.3 23.4”.
( For each sensor, two digit and the tenth place numbers are

displayed with a space between each temperature.)

?

Communication failure

The tables on page 97 and 98 show the typical command lists for controlling the projector. Please consult your

local dealer for further information of other commands.

Advertising