Verifying the Setting

The procedure described below should be followed to verify that the RS-422A mode had been
correctly set.

1.

Make sure the power switch is off. Plug the power cord into the printer and turn power
on.

2.

When the printer is on-line, press the STATUS key.

3.

If the mode has been correctly set, "RS-422A " should be indicated on the status page
printout. Please refer to the sample printout shown below.

Interface Signals

The pins in the printer’s RS-422A interface connector carry the signals listed in Table C.3 .

Table C.3. RS-422A Signal Pin Assignments

Pin

In/out

Signal

Description

1

FG

Frame ground

3

In

RDA

Receive data Inverted

7

SG

Signal ground

9

Out

SDA

Send data Inverted

10

Out

SDB

Send data

18

In

RDB

Receive data

Overview of Signals (RS-422A)

FG – Frame Ground – (Pin 1)

This pin is connected directly to the printer frame.

SG – Signal Ground – (Pin 7)

All signals can transmit between the printer and the host computer to send each signals with
a signal ground.

RDB – Receive Data – (Pin 18)
RDA – Receive Data Inverted – (Pin 3)

These pins carry asynchronous data sent from the computer to the printer. (differential input)

SDB – Send Data – (Pin 10)
SDA – Send Data Inverted – (Pin 9)

These pins carry asynchronous data sent from the printer to the computer. (differential output)