Prescribe ii frpo d0 command, C-11 – Kyocera FS-3700 User Manual

Page 111

Advertising
background image

H5: Protocol logic

Parameter value

Meaning

0

Combination of 1 and 3 below

1

DTR/DSR, positive logic

2

DTR/DSR, negative logic

3

XON/XOFF

4

ETX/ACK

5

XON/XOFF recognized only as protocol

The factory setting is 0.

H6: Buffer nearly-full threshold

This is a percentage from 0 to 99. The factory setting is 90.

H7: Buffer nearly-empty threshold

This is a percentage from 0 to 99. The factory setting is 70.

The factory settings of the buffer nearly-full and nearly-empty thresholds (H6 and H7) are sub-
ject to change without notification.

The gap between the nearly-full and nearly-empty thresholds allows the computer to send a
fairly large amount of data in a continuous stream.

H8: Received-data buffer size

This is the size of the input buffer, specified in units of 10K bytes. The factory-set value is 6
meaning 60K bytes.

Since DTR/DSR protocol is not used with the RS-422A standard, select a pa-
rameter value other than 0, 1, or 2 for the H5 setting when using the RS-422A
interface.

PRESCRIBE II FRPO D0 command

The PRESCRIBE II FRPO D0 command is provided to allow manipulating XON/XOFF when an er-
ror has occured on the serial interface. The following table summarizes the error status corre-
sponding to different D0 values.

Serial interface error

error not handled

error handled

Timing of XON transfer
to host while Ready or
Waiting

XON sent every 3-5
seconds

D0 = 0 (default)

D0 = 1

XON not sent

D0 = 10

D0 = 11

C.3. RS-232C/RS-422A Protocol

C-11