Baud rate=9600 bps, Data bits (character length)=8 bits,
Stop bits=1, Parity=None

The three RS-232C protocols are XON/XOFF and DTR. The printer performs all three of
them simultaneously, using positive logic for DTR.

If you are uncertain as to the printer’s current parameter settings, you can reset them to
the values listed above by following the manner described in the last page in this man-
ual.

8.

Set the computer to the same parameters as the printer. On many computers this can be
done by setting DIP switches before power is turned on. Another method is as follows:

In DOS, enter the following commands:

C>MODE COM1:96,N,8,1,P

C>MODE LPT1:=COM1

To test the interface, then enter:

CTRL P

C>DIR

CTRL P

The software settings made by the procedures above are temporary. On most comput-
ers, permanent settings must be made with DIP switches.

If you want to use a different baud rate or change any of the other RS-232C parameters,
you can use the printer’s FRPO (firmware reprogram) command. See the Programming
Manual
for details.

C.4. RS-232C Cable Connection

C-13