Controlling panpot (stereo position)

Panpot (CC#10) [Bn, 0A, vv]
(vv: value, where 00 is far left, 64 is center, and 127 is far
right)

When the above CC# is assigned to the ASSIGNABLE
PEDAL or as the B mode function of a REALTIME CON-
TROLS knob [1]–[4], operating that controller will transmit
Panpot messages, and the panning will change. When this
message is received, the result will be the same as when the
controller is operated.

• When you set the “Pan” (SEQ/S.PLAY 1.1–4/5) in

Sequencer mode or Song Play mode, or when you re-
select the song or return to the beginning of the measure
in Sequencer mode, Panpot messages (except for RND)
will be transmitted by each track whose “Status” is
BTH

, EXT, or EX2 (

☞p.75, p.117).

Post insert effect panpot (CC#08) [Bn, 08, vv]
(vv: value, where 00 is far left, 64 is center, and 127 is far
right)

When the above CC# is assigned to the ASSIGNABLE
PEDAL or as the B mode function of a REALTIME CON-
TROLS knob [1]–[4], operating that controller will transmit
Post Insert Effect Panpot messages, and the panning of the
sound following the insert effect will change. When this
message is received, the result will be the same as when the
controller is operated.

• In Program mode, this message is transmitted/received

on the global MIDI channel. In Combination, Sequencer,
and Song Play modes, this message is transmitted/
received on the MIDI channel specified for each insert
effect.

• When you set “Pan (CC#8)” (SEQ/S.PLAY 7.2–1a) in

Sequencer mode or Song Play mode, or when you re-
select the song or return to the beginning of the measure
in Sequencer mode, Post Insert Effect Panpot messages
will be transmitted by each track whose “Status” is
BTH

, EXT, or EX2 (

☞p.112, p.130).

Effect control

Effect control 1 (CC#12) [Bn, 0C, vv]
Effect control 2 (CC#13) [Bn, 0D, vv]
When the above CC# is assigned to the ASSIGNABLE
PEDAL or as the B mode function of a REALTIME CON-
TROLS knob [1]–[4], operating that controller will transmit
Effect Control 1/2 messages, and the specified dynamic
modulation will be controlled. When this message is
received, the result will be the same as when the controller is
operated.
Although various types of control change can be selected as
dynamic modulation sources, Effect Control 1 (CC#12) and 2
(CC#13) are dedicated for dynamic modulation.

Effect 1 depth (Send 2) (CC#91) [Bn, 5B, vv]
Effect 3 depth (Send 1) (CC#93) [Bn, 5D, vv]
When the above CC# is assigned to the ASSIGNABLE
PEDAL or as the B-mode function of a REALTIME CON-
TROL knob [1]–[4], operating that controller will transmit
Effect 1 Depth (Send 2) or Effect 3 Depth (Send 1) messages,
and the send level 1 or 2 to the master effects MFX1 or MFX2
will be controlled respectively. When this message is
received, the result will be the same as when the controller is
operated.

On the corresponding MIDI channels, this will simulta-
neously control the timbre/track setting as well as the set-
ting following the insertion effect.

• In Combination, Sequencer, and Song Play modes, the

actual send level of the timbre/track is determined by
multiplying this value with the send 1/2 settings for each
oscillator (PROG 7.1–1a). (

☞p.37, p.66, p.112 , p.130 “OSC

Send 1/2,” “S1 (Send1(MFX1)),” “S2 (Send2(MFX2))”)

• When you adjust “S1 (Send1(MFX1))” or “S2

(Send2(MFX2))” (SEQ 7.1–1a/2a, 7.2–1a) in Sequencer
or Song Play mode, or when you re-select a song or
return to the beginning of the measure in Sequencer
mode, Send 1/2 will be transmitted by each track whose
“Status” is BTH, EXT, or EX2. (

☞p.66, p.120).

Effect 2 depth (IFX1–5 on/off) (CC#92) [Bn, 5C, vv]
Effect 4 depth (MFX1 on/off) (CC#94) [Bn, 5E, vv]
Effect 5 depth (MFX2 on/off) (CC#95) [Bn, 5F, vv]
Separately from the effect on/off settings in each mode, “FX
SW” (GLOBAL 1.1–1b) allows you to turn off insert effects
IFX1–5 and master effects MFX1 and MFX2. If you check
“IFX1–5 Off,” “MFX1 Off” or “MFX2 Off,” the correspond-
ing message will be transmitted with vv=0 [00]. If you
uncheck

these settings, the corresponding message will be

transmitted with vv=127 [7F]. If you check these settings,
the corresponding effect(s) will be turned off as a group. If
you uncheck these settings, the on/off settings of each mode
will be used. The same applies to reception. (vv of 00 is off,
and 01 or greater is the original setting.) These messages are
transmitted/received on the global MIDI channel. (

☞p.39,

p.40 “IFX 1–5 On/Off”)

These messages are defined simply for use in adjusting
the effect levels, and may not have the same function on
another instrument connected to this instrument.

Using various controllers for control

Foot controller (CC#04) [Bn, 04, vv]
If the above CC# is assigned as the ASSIGNABLE PEDAL
function, this message will be transmitted when the control-
ler is operated.

• In Combination and Sequencer modes, transmission/

reception of this message can be turned on/off
independently for each timbre/track.

“Foot Pedal/Switch” (COMBI 4.4–2a, SEQ 4.4–3/4a)

Controller (CC#18) [Bn, 12, vv]
This message will be transmitted when this instrument’s
[VALUE] slider is operated.
This is valid in PROG 1.1: Play and COMBI 1.1: Play when
the program or combination “Program Select” is selected
(highlighted).

Knob modulation 1, 2, 3, 4 (CC#17, 19, 20, 21)
[Bn, 11, vv], [Bn, 13, vv], [Bn, 14, vv], [Bn, 15, vv]
If the above CC# are assigned to the B mode of REALTIME
CONTROLS [1]–[4] knobs, these messages will be transmit-
ted when the knobs are operated.

• In Combination and Sequencer modes, transmission/

reception of this message can be turned on/off
independently for each timbre/track (

☞p.55, 89

“Realtime Control Knob1, 2, 3, 4” COMBI/SEQ 4.3).

Controller (CC#83) [Bn, 53, vv]
If the above CC# is assigned to the B mode of REALTIME
CONTROLS [1]–[4] knobs, this message will be transmitted
when the knob is operated.

SW1 modulation (CC#80) [Bn, 50, vv]
SW2 modulation (CC#81) [Bn, 51, vv]
If the above CC# are assigned as the function of [SW1] or
[SW2], operating the switch will transmit this message with
vv=127 [7F] for ON, and vv=00 [00] for OFF. (These can also
be set as the B mode functions of the REALTIME CONTROL
knobs [1]–[4].)