76

Chapter 5: Using the Web-based Utility for Configuration
SNMP Tab

WebView Switches

To add an entry, click the paper and pencil icon. On the new screen that appears, you can configure the following
settings:

Group Name. Enter a name for the user-defined group to which access control rules are applied. The field
range is up to 30 characters.

Security Model. Defines the SNMP version attached to the group. The possible field values are:

SNMPv1 - SNMPv1 is defined for the group.

SNMPv2 - SNMPv2 is defined for the group.

SNMPv3 - SNMPv3 is defined for the group.

Security Level. Defines the security level attached to the group. Security levels apply to SNMPv3 only. The
possible field values are:

No Authentication - Indicates that neither the Authentication nor the Privacy security levels are assigned
to the group.

Authentication - Authenticates SNMP messages, and ensures the SNMP messages origin is
authenticated.

Privacy - Encrypts SNMP message.

Operation. Defines the group access rights. The possible field values are:

Read - The management access is restricted to read-only, and changes cannot be made to the assigned
SNMP view.

Write - The management access is read-write and changes can be made to the assigned SNMP view.

Notify - Sends traps for the assigned SNMP view.

Click the Submit button to save your entry.

Figure 5-71: SNMP - add Group Profile