Diagnostic error codes

Refer to the following diagnostic error codes when using the diagnostic tests. See “Running tests” on page
37
for the specific type for information about the Diagnostic programs.

In the following index, X can represent any number.

Diagnostic Error Code

FRU/Action

000-000-XXX BIOS Test Passed

No action

000-002-XXX BIOS Timeout

1. Flash the system. See “Flash update procedures”

on page 185

2. System board

000-024-XXX BIOS Addressing test failure

1. Flash the system. See “Flash update procedures”

on page 185

2. System board

000-025-XXX BIOS Checksum Value error

1. Flash the system. See “Flash update procedures”

on page 185

2. System board

000-026-XXX FLASH data error

1. Flash the system. See “Flash update procedures”

on page 185

2. System board

000-027-XXX BIOS Configuration/Setup error

1. Run Setup

2. Flash the system. See “Flash update procedures” on

page 185

3. System board

000-034-XXX BIOS Buffer Allocation failure

1. Reboot the system

2. Flash the system. See “Flash update procedures” on

page 185

3. Run memory test

4. System board

000-035-XXX BIOS Reset Condition detected

1. Flash the system. See “Flash update procedures”

on page 185

2. System board

000-036-XXX BIOS Register error

1. Flash the system. See “Flash update procedures”

on page 185

2. System board

000-038-XXX BIOS Extension failure

1. Flash the system. See “Flash update procedures”

on page 185

2. Adapter card

3. System board

000-039-XXX BIOS DMI data error

1. Flash the system. See “Flash update procedures”

on page 185

2. System board

000-195-XXX BIOS Test aborted by user

Information only Re-start the test, if necessary

000-196-XXX BIOS test halt, error threshold exceeded

1. Press F3 to review the log file

2. Re-start the test to reset the log file

46

Hardware Maintenance Manual Lenovo 3000 J Series

Advertising