Diagnostic Error Code

FRU/Action

025-027-XXX IDE interface Configuration/Setup error

1. IDE signal cable

2. Flash the system. See “Flash update procedures” on

page 185

3. Reseat IDE signal cable

4. IDE device

5. System board

025-02X-XXX 025-03X-XXX 025-04X-XXX IDE Interface
failure

1. IDE signal cable

2. Check power supply

3. Reseat IDE signal cable

4. IDE device

5. System board

025-195-XXX IDE interface Test aborted by user

Information only Re-start the test, if necessary

025-196-XXX IDE interface test halt, error threshold
exceeded

1. Press F3 to review the log file

2. Re-start the test to reset the log file

025-197-XXX IDE interface test warning

1. Make sure the component that is called out

is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 41

2. Re-run test

3. Replace the component that is called out in warning

statement

4. Replace the component under test

025-198-XXX IDE interface test aborted

1. If a component is called out, make sure it is

connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 41

2. Flash the system and re-test. See “Flash update

procedures” on page 185

3. Go to “Undetermined problems” on page 67

025-199-XXX IDE interface test failed, cause unknown

1. Go to “Undetermined problems” on page 67

2. Flash the system and re-test. See “Flash update

procedures” on page 185

3. Replace component under function test

030-000-XXX SCSI interface Test Passed

No action

030-00X-XXX 030-01X-XXX SCSI interface failure

1. SCSI signal cable

2. Check power supply

3. SCSI device

4. SCSI adapter card, if installed

5. System board

030-027-XXX SCSI interface Configuration/Setup error

1. SCSI signal cable

2. Flash the system. See “Flash update procedures” on

page 185

3. SCSI device

4. SCSI adapter card, if installed

5. System board

56

Hardware Maintenance Manual Lenovo 3000 J Series