Lenovo J SERIES 3000 User Manual

Page 57

Advertising
background image

Diagnostic Error Code

FRU/Action

005-199-XXX Video test failed, cause unknown

1. Go to “Undetermined problems” on page 67

2. Flash the system and re-test. See “Flash update

procedures” on page 185

3. Replace component under function test

005-2XX-XXX 005-3XX-XXX Video subsystem error

1. Video card, if installed

2. System board

006-000-XXX Diskette interface Test Passed

No action

006-0XX-XXX Diskette interface error

1. Diskette drive Cable

2. Diskette drive

3. System board

006-195-XXX Diskette interface Test aborted by user

Information only Re-start the test, if necessary

006-196-XXX Diskette interface test halt, error threshold
exceeded

1. Press F3 to review the log file

2. Re-start the test to reset the log file

006-197-XXX Diskette interface test warning

1. If a component is called out, make sure it is

connected and/or enabled

2. Re-run test

3. Replace the component that is called out in warning

statement

4. Replace the component under test

006-198-XXX Diskette interface test aborted

1. If a component is called out, make sure it is

connected and/or enabled

2. Flash the system and re-test. See “Flash update

procedures” on page 185

3. Go to “Undetermined problems” on page 67

006-199-XXX Diskette interface test failed, cause
unknown

1. Go to “Undetermined problems” on page 67

2. Flash the system and re-test

3. Replace component under function test

006-25X-XXX Diskette interface Error

1. Diskette drive cable

2. Diskette drive

3. System board

011-000-XXX Serial port Interface Test Passed

No action

011-001-XXX Serial port Presence

1. Remove external serial device, if present

2. Run setup, enable port

3. System board

011-002-XXX 011-003-XXX Serial port Timeout/Parity
error

System board

011-013-XXX 011-014-XXX Serial port Control
Signal/Loopback test failure

System board

011-015-XXX Serial port External Loopback failure

1. Wrap plug

2. System board

Chapter 7

.

Symptom-to-FRU Index

51

Advertising