INPUT RECTIFIER BRIDGE REMOVAL AND REPLACEMENT (continued)

7. Carefully remove the input rectifier bridge.

8. When installing a new input rectifier apply a

thin coating of Penetrox A-13 Heat Sink
Compound (Lincoln E2529) to the mating
surfaces. Torque the mounting cap screws
and nuts to 44 in-lbs.

9. Reconnect the 10 leads to the correct ter-

minals and torque the phillips head
screws to 31 in-lbs.

10. Apply Essex DC-4-8 Insulating Com-

pound to all six screw heads and termi-
nals. The heavy input lead terminals
should be against the rectifier terminals.