TROUBLESHOOTING & REPAIR

F-19

F-19

PRO-CUT 55

PRIMARY POWER BOARD RESISTANCE TEST AND

CAPACITOR VOLTAGE TEST (continued)

FIGURE F.3 – PRIMARY POWER BOARD REMOVAL

PRIMARY POWER
BOARD WITH
INPUT FILTER
CAPACITORS

+

+

CAPACITOR (C2)
TERMINALS

CAPACITOR (C1)
TERMINALS

PRO-CUT

POWER G3172-[ ]

207

202

206

203

201

204

205

208

TEST PROCEDURE

1.

Remove main input power to the Pro-Cut
55.

2. Perform the Input Filter Capacitor

Discharge Procedure detailed earlier in
this section.

3. Locate the primary power board and asso-

ciated lead locations. See Figure F.3.

4. Carefully remove the main transformer pri-

mary leads #201, #204, #205 and #208
from the power board.

5. Use the analog ohmmeter to perform the

test outlined in Table F.2.