TROUBLESHOOTING & REPAIR

F-15

F-15

PRO-CUT 55

INPUT RECTIFIER TEST (continued)

TEST PROCEDURE

1. Remove main input power to the machine.

2. Perform the Input Filter Capacitor

Discharge Procedure detailed earlier in
this section.

3. Locate the input rectifier (D1) and lead loca-

tions. See Figure F.2.

4. With the phillips head screw driver, remove

leads #207, 207A and #209 from the rectifi-
er.

5. Use the analog ohmmeter to perform the

tests detailed in Table F.1. See the Wiring
Diagram.

FIGURE F.2 – INPUT RECTIFIER AND LEADS

#207
#207A

#209 (+)

C

B

A

(-)