TROUBLESHOOTING & REPAIR

F-35

F-35

PRO-CUT 55

(T2) AUXILIARY TRANSFORMER TEST (continued)

FIGURE F.8 – T2 AUXILIARY TRANSFORMER

PLUG J22

PLUG J21

T2 AUXILIARY
TRANSFORMER

PLUG J21

PLUG J22 (6 Cavity)

9

8

6

5
4

2

6

4

3

1

(H5)

(H2)

(H4)
(H3)

(H1)

2

7

8

2
1

5

(H5)
(H4)

(H2)

(H3)
(H1)

PLUG J22 (8 Cavity)

PROCEDURE

1. Remove main input power to the Pro-Cut 55

machine.

2. Perform

the

Input Filter Capacitor

Discharge Procedure detailed earlier in this
section.

3. Locate the auxiliary transformer just behind

the input line switch on the lower right side of
the machine.

4. Locate and disconnect plugs J21 and J22

from the wiring harness. Cut any necessary
cable ties. See Figure F.8.

5. Carefully apply the 230 VAC isolated supply

to leads H1 (1J22) and H3 (2J22) of the aux-
iliary transformer. These leads are located in
plug J22.

6. Carefully check for the presence of the fol-

lowing primary and secondary voltages at the
appropriate leads at plugs J21 and J22. See
Figure F.8 and Table F.6..