5. Locate the control board and the five molex

type plugs connected to it. See Figure F.17.

6. Carefully remove the five molex type plugs by

depressing the locking tabs and gently
extracting the plugs from the P.C. board
receptacles.

7. Using the needle-nose pliers and screwdriv-

er, gently remove the control board from the
eight mounting pins by depressing the tabs
on the mounting pins and carefully removing
the board from the pins. See Figure F.18.

Be sure to follow the recommended static-free
methods for handling printed circuit boards.
Failure to do so can result in permanent damage
to the equipment.

8. When replacing the control board, align the

mounting holes with the eight mounting pins
and gently slide the P.C. board onto the
mounting pins until the board “snaps” onto
the pins.

9. Replace the five molex type plugs in their

respective receptacles. Be certain they are
securely in place.

10. Carefully reposition the front assembly in

place and install the four mounting screws
previously removed.

11. Inspect, clear and secure all leads before

installing the case wrap-around reassembly.

12. Using the 5/16” nut driver, install the case

wraparound.

TROUBLESHOOTING & REPAIR

F-52

F-52

PRO-CUT 55

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

MOUNTING
PIN (8)

CONTROL
BOARD

DEPRESS
LOCKING TAB ON
MOUNTING PIN

FIGURE F.18 - CONTROL BOARD REMOVAL FROM MOUNTING PINS

CONTROL BOARD REMOVAL AND REPLACEMENT (continued)