TROUBLESHOOTING & REPAIR

F-29

F-29

PRO-CUT 55

TORCH CONTINUITY AND SOLENOID TEST (continued)

TEST PROCEDURE

1. Remove input power to the Pro-Cut 55

machine.

2.

Remove the torch assembly from the
machine.

3. Using the ohmmeter, check the torch resis-

tances per Table F.5.

NOTE: Take the “Pin” test point measurements

at the machine end of the torch assem-
bly. See Figure F.5.

FIGURE F.5 - TORCH CONNECTOR - MACHINE END

1

2

3

4

5

6

7

8

9

Not used
inside
power
source

White Pair

Black Pair

Red Leads

Blue Leads

Torch Solenoid

Vent Tube

Electrode Lead

Air Hose

White & Black Pairs

Connector

ELECTRODE

BODY (nozzle)

Electrode is

insulated from

Brass Body

outside

center

flex tubes

Pilot path / air tube

crimp

fitting

N.O.

Torch Trigger