The air low led is lit, The safety led is flashing, The safety led is lit and ready – Lincoln Electric PRO-CUT 55 SVM140-A User Manual

Page 45: Troubleshooting & repair, Caution

Advertising
background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TROUBLESHOOTING & REPAIR

F-8

F-8

PRO-CUT 55

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-888-935-3877.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

LED FUNCTION PROBLEMS

The Air Low LED is lit.

1. Make sure there is at least 70

psi (448 kPa) of air pressure
connected to the gas connec-
tion at the back of the Pro-Cut
55.

2. Press the purge button and set

the regulator to 70 psi (448
kPa). Do not reset the air pres-
sure while the air is off (not flow-
ing).

1. The pressure switch (S5) or

associated leads may be faulty.
See the Wiring Diagram.

2. The control board may be faulty.

Replace.

The Safety LED is flashing.

1. Make sure there is a Lincoln

PCT 80 torch connected prop-
erly to the Pro-Cut 55.

2. Make sure the torch consum-

ables are in place and in good
condition.

1. Perform the Torch Continuity

and Solenoid Test.

2. Check leads “N”, “E”, #364,

and #369 between the torch
receptacle and the output
board. See the Wiring Diagram.

3. The output board may be faulty.

Replace.

The Safety LED is lit and ready.

1. Press the reset button. If the

torch and consumables are
properly installed, the Safety
LED should turn off.

1. The reset button or associated

wiring may be faulty. See the
Wiring Diagram.

2. Perform the Torch Continuity

and Solenoid Test.

3. The control board may be faulty.

Replace.

4. If the machine operates normal-

ly with the Safety LED on, the
display board may be faulty.
Replace.

Advertising