Pro-cut troubleshooting flowchar t, Troubleshooting & repair, F-10 – Lincoln Electric PRO-CUT 55 SVM140-A User Manual

Page 47

Advertising
background image

TROUBLESHOOTING & REPAIR

F-10

F-10

PRO-CUT 55

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

System is functional. If

performance problems

exist, see performance

recommendations

Replace the

output board.

Does

arc go out within

5 seconds?

Choke may be

shorted. Replace.

Make a short cut and pull

back into pilot mode.

Hold trigger until pilot arc

goes out.

Make sure clamp

is secured to work

Will arc transfer

to work piece?

Is pilot arc smooth

and continuous?

Disassemble torch

check for oil and/or

water contamination

Perform the Torch

Continuity and

Solenoid Test.

Consumables may

be worn. Replace.

After 2 seconds of

preflow, does pilot

arc start?

Does preflow gas

flow from torch?

Pull gun trigger

and hold

Press PURGE button, set

pressure to 70psi, then

release. If no air flow from

torch, perform Gas

Solenoid Test.

Is green power

LED is only one lit

Wait 5

seconds

Turn on

START

Make sure machine

reconnect is properly

set for the input voltage

Are all LED’s

flashing?

Perform the Primary

Power Board

Resistance Test

Perform the

Auxiliary

Transformer Test

Perform the

Input Rectifier

Test

Are all LED’s

lit?

The microprocessor

is faulty, replace

the control board

Are all LED’s

off?

Perform the

Auxiliary

Transformer Test

Perform the

Input Rectifier

Test

Perform the

Low Voltage

Circuit Test

Air low LED?

Safety LED?

Thermal LED?

Connect air supply,

check air pressure

sensor

Clean or replace

consumables

Is safety LED

flashing?

Perform the

Torch Continuity

and Solenoid Test

Press

Reset button

Check leads "N", "E", #364,

& #369 between the torch

receptacle and the

output board

Thermostats tripped. Leave

machine on and allow to cool.

Make sure fans are functioning.

If problems persist, turn machine off

and blow out inside. Make sure air

louvers are not blocked. If thermal

LED never turns off, check thermostats

and leads. Control board may be

faulty. If machine operates normally

while thermal LED is lit, the display

board may be faulty.

Contact Lincoln

Electric Service

Department

Make sure torch is

connected properly,

then perform the

Trigger Circuit Test

Output board

may be faulty

Check torch cable for

kinks or restriction

to air flow

Perform the

Torch Continuity

and Solenoid Test

Electrode Solenoid

in gun handle may

be faulty

PRO-CUT

TROUBLESHOOTING

FLOWCHAR

T

Y

Y

Y

Y

Y

YY

Y

Y

Y

Y

Y

N

N

N

N

N

N

NN

N

N

N

N

N