TROUBLESHOOTING & REPAIR

F-33

F-33

PRO-CUT 55

AIR/GAS SOLENOID TEST (continued)

TEST PROCEDURE

1. Remove input power to the machine.

2. Perform the Input Capacitor Discharge

Procedure detailed earlier in this section.

3. Locate the air solenoid and leads. See Figure

F.6.

4. Carefully remove plug J31 from the output

power board. See Figure F.7.

5. Check the coil resistance of the solenoid at

plug J31 pin-6 to J31 pin-5. Normal resis-
tance is approximately 20 ohms. If the resis-
tance is abnormal, check the continuity (zero
or very low resistance) of leads #366 and
#361 between the solenoid and plug J31.

See the Wiring Diagram. If the leads are
good, the solenoid coil may be faulty.

6. Carefully apply the 12 VDC supply to the

solenoid leads at plug J31 (positive to J31
pin-6 lead #366 and negative to J31 pin-5
lead #361).

With proper air pressure applied, the sole-
noid should activate and air should flow.

If the solenoid activates but air does not
flow, check for a restriction in the air line.

7. Install plug J31 back into the output power

board.

FIGURE F.6 – AIR SOLENOID

AIR SOLENOID

G3326 - [ ] PRO-CUT 55 OUTPIUT

x40

J33

X4

(B11)

X2

(B12)

R5

Test

Point

B21

J32

x20

J31

B1

B2

R5

FIGURE F.7 – PLUG J31 LOCATION