Troubleshooting & repair, Test procedure, Warning – Lincoln Electric PRO-CUT 55 SVM140-A User Manual

Page 58

Advertising
background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TROUBLESHOOTING & REPAIR

F-21

F-21

PRO-CUT 55

PRIMARY POWER BOARD RESISTANCE TEST AND

CAPACITOR VOLTAGE TEST (continued)

CAPACITOR VOLTAGE TEST

This test will help the technician to determine if
the input filter capacitors are being charged
equally to the correct voltage levels.

NOTE: This test should only be conducted with
the Pro-Cut 55 connected for 400 VAC and
above, and with the appropriate input voltage
applied.

TEST PROCEDURE

1. Remove main input power to the Pro-Cut

55.

2. Perform the Input Filter Capacitor

Discharge Procedure detailed earlier in
this section.

3. Locate and familiarize yourself with the

capacitor test locations on the primary
power board. See Figure F.3.

4. The following tests will be performed with

the input power applied to the Pro-Cut 55.
BE CAREFUL. ALWAYS REMOVE THE
INPUT POWER AND PERFORM THE
INPUT FILTER CAPACITOR DISCHARGE
PROCEDURE BEFORE TOUCHING ANY
MACHINE COMPONENT.

ELECTRIC SHOCK

can kill.

• Have an electrician install and

service this equipment.

• Turn the input power off at the

fuse box before working on
equipment.

• Do not touch electrically hot parts.

5. Apply the correct input power† and turn ON

the Pro-Cut 55.

NOTE: This test should only be conducted

with the Pro-Cut 55 reconnect switch
and “A” jumper configured for 400
VAC and above.

WARNING

Advertising