Ch4. Symptom-to-part index

FRU or action, in sequence

Symptom / Error

1. DIMM
2. System board

02F6
Software NMI failed

1. DIMM
2. System board

02F5
DMA test failed

1. Load “Setup Default” in BIOS Setup Utility.
2. Replace the backup battery.
3. System board.

02F4
EISA CMOS not writable

1. Load “Setup Default” in BIOS Setup Utility.
2. System board.

02D0
System cache error – Cache disabled
(RAM cache failed and BIOS disabled)

1. Floppy diskette drive.
2. External FDD cable.
3. I/O card.

02B3
Incorrect Drive B type

1. Floppy diskette drive.
2. External FDD cable.
3. I/O card.

02B2
Incorrect drive A type – Floppy diskette drive
error

Set up the diskette type in BIOS Setup Utility.

02B1
Diskette drive B error

Set up the diskette type in BIOS Setup Utility.

02B0
Diskette drive A error

Load Setup Defaults in BIOS Setup Utility.

0281: Memory Size found by POST differed
from EISA CMOS

1. Load “Setup Default” in BIOS Setup Utility.
2. DIMM.
3. System board.

0280
Previous boot incomplete
- Default configuration used

Run BIOS Setup Utility to reset the time and date.

0271
Check date and time settings – Date and time
error.

1. Replace the backup battery and run BIOS

Setup Utility to reset the time and date.

2. System board.

0260
System timer error

Reset the password by running BIOS Setup Utility.

0252
Password checksum bad – The password is
cleared.

Replace the backup battery and run BIOS Setup Utility
to reset the time and date.

0251
System CMOS checksum bad
– System CMOS checksum is not correct.
– Default configuration used.