Installation, 18 projection scheme, Installation geometry – Panasonic PT-D7600U User Manual

Page 18: Adjusting the leveling feet, Side view

Advertising
background image

18

Projection scheme

This projector is applicable to any of the following four
projection schemes. Select the most suitable scheme
to the situation of your location. Use the OPTION
menu on the menu screen to choose the desired
projection scheme. (Refer to page 71)

Rear projection

Front projection

Table standing

Ceiling mount

Table standing

Ceiling mount

(Default position)

Installation geometry

When planning the projector and screen geometry,
refer to the figures below and the information on the
next page for reference. After the projector is roughly
positioned, picture size and vertical picture positioning
can be finely adjusted with the powered zoom lens and
lens shifting mechanism.

< Front >

< Side >

Leveling feet

Installation

Adjusting the leveling feet

The four leveling feet mounted at the bottom of the projector
are level-adjustable (0 mm–33 mm) which can be used
when the floor surface is not horizontal.

H

SH

L

L

H

Side view

When optional ceiling
mount bracket (ET-PKD75)

Screen

(unit: mm/inch)

438-558

(17.2"-21.9")

237

(9.3")

L

SW

314

86

140

175

468

117

L

1

Top view

Screen

(unit: mm/inch)

(18.4")

(5.5")

(12.3")

(3.4")

(6.9")

(4.6")

L

: Projection distance

SH : Height of the image
SW: Image width
H

: Vertical distance between the

lens center level and the bottom
edge of the projected image

*For PT-D7500U,

H= -0.2 x SH to
1.2 x SH
For PT-D7600U,
H= 0 to SH

Lens

Dimension of L1 (Approx.)

ET-D75LE1/ET-D75LE1SC

102 (4")

ET-D75LE2/ET-D75LE2SC

86.5 (3.4")

ET-D75LE3/ET-D75LE3SC

90 (3.5")

ET-D75LE4/ET-D75LE4SC

113.9 (4.5")

ET-D75LE5

190 (7.5")

Advertising