Option settings

Lamp select

Two internal lamps in the projector can be used either
in “DUAL” or “SINGLE” mode depending on user's
needs or viewing conditions.
In the “SINGLE” mode, the projector may automatically
switches between one lamp and the other, or one of
the lamps can be specified.

“DUAL”: Two lamps illuminate.
“LAMP 1”: One lamp illuminates.
(Lamp Unit 1 is always used)
“LAMP 2”: One lamp illuminates.
(Lamp Unit 2 is always used)
“SINGLE”: One of the lamps illuminates.
(The lamp with shorter operating hours is automatically
selected)

Lamp power

The luminance of the projection lamp can be changed
depending on user's needs or the viewing conditions.

“HIGH”: Set when high brightness is necessary.
“LOW”: Set when high brightness is not necessary.

Note

LAMP SELECT

DUAL

LAMP1

LAMP2

SINGLE

LAMP POWER

LOW

HIGH

Lamp cooling time

The user can change the length of time for cooling
down lamps after the power off.

LAMP COOLING TIME NORMAL

SHORT

RGB2 select

The RGB2 terminal can be used either for RGB2 IN or
RGB1 OUT function.

RGB2 SELECT

RGB2 IN

RGB1 OUT

Position of on-screen
indications

The user can specify the position of the on-screen
indications

“1”: Top of the screen
“2”: Middle of the screen
“3”: Bottom of the screen

OSD POSITION

1

2

3

Note

• When set to “LOW”, it is possible to

reduce power consumption, reduce
operating noise and extend lamp
service life.

Note

• When set to “SHORT”, operating noise

increases a little.

• If any of “LAMP 1”, “LAMP 2” and

“SINGLE” has been selected, when a
currently lit lamp expires, or is turned
off due to the elapsed time of lamp
lighting exceeding 1500 hours, the
other lamp will be turned on.
If “DUAL” has been selected, when
either of the two lamps expires, or is
turned off due to the elapsed time of
lamp lighting exceeding 1500 hours,
the other lamp with elapsed time not
exceeding 1500 hours continues
lighting.
Further, if the elapsed time exceeds
1500 hours for both lamps, the
projector will enter a standby state.

• If only one lamp is mounted, select

“LAMP 1” or “LAMP 2” according to
the relevant lamp unit.
In “LAMP 1” or “LAMP 2” mode, if the
corresponding lamp is not installed,
the other lamp will turn on.

• If the lamp selection is changed,

picture is muted during lamp switching
execution. (7-25sec.)

(Approx. 240 secs.)

(Approx. 160 secs.)