How to switch the input impedance (signal level) of the synchronization signal

When the ET-MD95RGB input module (sold separately) is mounted, the user can switch the input impedance
(signal level) of the synchronization signal with the analog RGB input.
Choose 75

Ω when connecting with the equipment whose synchronization output impedance is 75 Ω such as a

signal selector, or switch to HI-Z (TTL) when connecting with the equipment whose synchronization output is TTL
such as a video card of a PC.

OPTION

SYSTEM INFORMATION
VIDEO SETTING
AUTO SETUP
SYNC. TERM

75

P IN P

ON

FUNC1

P IN P

CONTRAST MODE

HIGH

PASSWORD

:MENU SELECT
:CHANGE

Press the “MENU” button.

The MAIN MENU screen will be displayed.

Select “OPTION” with the
buttons.

MAIN MENU
PICTURE
POSITION
LANGUAGE
OPTION
TEST PATTERN
SIGNAL LIST

:MENU SELECT
ENTER:SUB MENU

Press the “ENTER” button.

The OPTION screen will be displayed.

Select “SYNC. TERM” with the
buttons.

Switch the input impedance (signal
level) of the synchronization signal
with the

buttons.

• These buttons toggle between 75

Ω and HI-Z

(TTL).

SYNC. TERM

75

HI-Z (TTL)

Amplitude: 0.6V[p-p] to 4.0V[p-p]

High level: 2.0 V or over
Low level: 0.8 V or lower

Input impedance

Signal level

75

1 k

• Switch the input impedance according to the input signal.
• The factory default is 75

Ω.

• The clock phase and image position may become out of balance during this switching operation.

Please make readjustment accordingly.