109

The underlining in the variable range column indicates the setting in the preset mode.

Setting menu screens

FILM (CAM) MAIN MENU 4

DIAGNOSTIC screen

The usage statuses and software versions are
displayed on this screen.

Item

Variable

range

Remarks

CAMSOFT (IN)

==

VF

display

ENG

For displaying the version
of the software for the
built-in flash memory.

CAMSOFT (OUT)

==

ENG

For displaying the version
of the software for the
external flash memory.

CAM TABLE

==

ENG

For displaying the version
of the gamma table.

PLD (CAM)

==

ENG

For displaying the version
of the software for the
camera system computer.

PLD (SHD)

==

ENG

For displaying the version
of the software for the
shading.

SUB menu

VF

display

Remarks

S/N

ENG

Index for opening the S/N
measurement screen.

MODULATION

ENG

Index for opening the modulation
measurement screen.

RESOLUTION

ENG

Index for opening the resolution
measurement screen.

SENSITIVITY

ENG

Index for opening the sensitivity
measurement screen.

EVALUATION screen

The items which are measured for evaluation
purposes are set on this screen.
(S/N, MODULATION, RESOLUTION, SENSITIVITY)

<Note>
For details on how to release ENG SECURITY, consult your nearest
service center.

OPTION screen

The engineer menu display is selected on this screen.

Item

Variable

range

Remarks

ENG SECURITY

ON
OFF

VF

display

ENG

For selecting whether to
display the engineer
menu.
ON : The engineer menu

is not displayed.

OFF : The engineer menu

is displayed.

SHD, ABB SW
CRTL

ON
OFF

ENG

For selecting whether to
automatically correct black
shading when the AUTO W/B
BAL switch is pressed
continuously for 8 seconds or
more on the ABB side.
ON : Black shading is

corrected automatically.

OFF : Black shading is not

corrected automatically.

AWB AREA

25%
50%
90%

ENG

For selecting the white
balance search area.

AWB & ABB
OFFSET

ON
OFF

ENG

For setting how gain and
pedestal values, which are
set on the ROP screen of
FILM (CAM) MAIN MENU
1, are to be processed
after auto white balance
and auto black balance
are performed.
ON : Settings are added.
OFF : The values are reset

to zero.

CAM MENU SEL

VIDEO MENU
FILM MENU

ENG

For setting the unit’s
operation mode.
VIDEO MENU:

The unit is set to the
video mode.

FILM MENU:

The unit is set to the film
mode.

SYSTEM FREQ.

59.94Hz
60.00Hz

ENG

For setting the unit’s frame
frequency.

Advertising