Warning System

Warning Description Tables

If a problem is detected immediately after the power is turned on, or during operation, this will be indicated by the
WARNING lamp, lamps inside the viewfinder and a warning tone.

Priority

Warning

type

LCD or viewfinder

indication

Tally lamp

Warning

lamp

Alarm

tone

*6

Warning description

and recording/playback

operation

Countermeasures

1 System error

SYSTEM ERROR
Cause indication *

1

Red

blinking

Blinks 4
times per
second

Blinks 4
times per
second

Continuous
tone

P2 microprocessor or control
failure. Operation stops.

Check the cause
indication *

1

and

consult your
distributor.

2

Incorrect
P2 card
removal

TURN POWER OFF
Blinks red

Blinks 4
times per
second

Blinks 4
times per
second

Continuous
tone

A P2 card was removed
during access and card data
was corrupted.
Both access LEDs light
orange.

Turn off the power.
Repair the P2 card if
the clips on the card
are corrupted.

3

The
battery is
exhauseted

LOW BATTERY Red
blinking, and the battery
level bar blinks with
the empty status. (This
indication appears also
when MENU indications
have been turned OFF.)

Blinks 1 time
per second

Lights

Continuous
tone

The battery is exhausted.
Recording and playback
stop. The camera stops
automatically when the
voltage drops.

Replace the battery.

4

P2 card fully
recorded

P2

FULL

Blinks red (appears only for
3 seconds in MCR mode.)

Blinks 4
times per
second after
completion
of recording.

Lights after
completing
recording

Continuous
tone after
completing
recording

No more space on P2
cards left for recording.Stop
recording.

*3

Delete clips that are
no longer needed or
insert a new card.

5

Recording
error

REC WARNING
Cause indication

*2

Blinks

red

Blinks 4
times per
second

Blinks 4
times per
second

Intermittent
tone 4
times per
second

A recording error has
occurred. The error may
terminate recording or let it
continue.

*4

Turn the power off
and then back on
again and check
recording and
playback. Replace
any P2 card that
does not enable
normal recording.

6

Irregular
reference
signal

TEMPORARY PAUSE
IRREGULAR FRM SIG
Blinks red.

Blinks 4
times per
second

Blinks 4
times per
second

Intermittent
tone 4
times per
second

An irregular reference
signal input to GENLOCK IN
prevents normal recording
by pausing recording. The
recorded clip is divided.
• Recording resumes when

the signal returns to normal.
Recording does not resume
if interval, one-shot or loop
recording is in progress.

Check the
GENLOCK IN signal.

7

Drop in
reception
quality of
wireless
receiver
transmission

WIRELESS RF
Blinks red

Blinks 4
times per
second
(Recording
only)

Blinks 4
times per
second

No

Indicates poor reception
from the wireless receiver.
Recording continues but
wireless microphone cannot
be received.

Check microphone
power supply and
receiver reception
status.