DC OUT Connector and External REC Start/Stop Switch Connection

The DC OUT connector on the camera can output a 1.5 A
current.
Connecting an external switch to this connector enables
REC Start and Stop control.
An LED can be connected and used as a tally lamp, which
is convenient when the camera is mounted on a crane
during recording.

DCOUTconnector

1

2

3

4

LED

REC

Cableconnector

HR10A-P-P()

HiroseElectricCo.

Max.0mA

Resistance

Start/Stop

1: GND

2: TALLY OUT

The AG-HPX300P has open collector output
TALLY ON:

Low impedance

TALLY OFF:

High impedance

3: REC Start/Stop switch

This pin is connected in parallel with the REC button
and the lens VTR button.

4: +12 V

NOTE:

• Make sure that the total current output by DC OUT, REMOTE,

VF and LENS connectors does not exceed 2.5 A.

• Be sure to check polarity before connecting an external

device as incorrect connection could lead to damage.