Figure 2-9. stopping data transfer using a trigger, Start and stop trigger, Figure 2-10. using a start and stop trigger – National Instruments 653X User Manual

Page 38: Start and stop trigger -20, Pattern-matching trigger (input only)

Advertising
background image

Chapter 2

Using Your 653X

653X User Manual

2-20

ni.com

data is in the buffer, transfer stops. If the stop trigger arrives before all the
pretrigger data is acquired, NI-DAQ returns an error.

Figure 2-9. Stopping Data Transfer Using a Trigger

Start and Stop Trigger

When using a start and stop trigger, transfer starts upon receiving a trigger
on the start trigger line (ACK/STARTTRIG pin) and ends upon receiving
a trigger on the stop trigger line (STOPTRIG pin) and a predetermined
amount of pretrigger and posttrigger data is saved in the buffer. If a stop
trigger is received before a start trigger, it is ignored. If the stop trigger
arrives before all the pretrigger data is acquired, NI-DAQ returns an error.

Figure 2-10. Using a Start and Stop Trigger

Pattern-Matching Trigger (Input Only)

Instead of using an external signal on the start/stop trigger pins on the
I/O connector, you may start or stop (not both) an operation once a
user-specified digital pattern is matched or not matched.

Specify four parameters to set up a pattern-matching trigger:

Whether it is a start or stop trigger

The data pattern to be detected/matched

The mask, which selects the bits of interest for pattern comparison
(0 for bits not of interest)

REQ

STOPTRIG

Pretrigger Data

Posttrigger Data

REQ

STOPTRIG

ACK (STARTTRIG)

Pretrigger Data

Posttrigger Data

Advertising