Appendix c connecting signals with accessories, Control signals, R to table c-1 – National Instruments 653X User Manual

Page 98: Connecting signals with accessories

Advertising
background image

© National Instruments Corporation

C-1

653X User Manual

C

Connecting Signals with
Accessories

This appendix describes how to connect signals to your 653X device. Use
the first part of the appendix to acquaint yourself with the device control
signals. Then go to appropriate pinout diagrams (68 or 50-pin), which
display the layout of pin locations.

Control Signals

Use the four control signals to regulate/control the timing of your data
transfer when using the handshaking and pattern I/O modes. The direction
and function of each signal varies, depending on the mode of operation,
as shown in Table C-1.

Table C-1. Control Signals for Handshaking I/O and Pattern I/O

Signal Name

Handshaking I/O

Pattern I/O

Direction

Function

Direction

Function

REQ<1..2>

Input

Request—Indicates

that the peripheral

device is ready

Input or

Output

Request—

Clocks the data transfer

ACK<1..2>

or

STARTTRIG<1..2>

Output

Acknowledge—

Indicates the 653X

device is ready

Input

Start trigger

STOPTRIG<1..2>

N/A

N/A

Input

Stop trigger

PCLK<1..2>

Input or

Output

Peripheral clock

N/A

N/A