Timing Diagrams

© National Instruments Corporation

3-11

653X User Manual

Figure 3-8. Burst Output Timing Diagram (PCLK Reversed)

Parameter

Description

Minimum

Maximum

Input Parameters

t

rs

Setup time from REQ valid to PCLK

12

t

rh

Hold time from PCLK to REQ invalid

0

Output Parameters

t

pc

PCLK cycle time

50

700

1

t

pw

PCLK high pulse duration

t

pc

/2 – 5

t

pc

/2 + 5

t

pa

PCLK to ACK valid

18

t

ah

Hold time from PCLK to ACK invalid

3

t

pdo

PCLK to output data valid

28

t

doh

Hold time from PCLK to output data
invalid

4

t

dis

Setup time from input data valid to PCLK

0

t

dih

Hold time from PCLK to input data invalid

0

1

t

pc

= programmable delay from 100 to 700 ns, or 50 ns if programmable delay is 0. Timebase stability for the board

20 MHz clock source is 50 ppm.

All timing values are in nanoseconds.

PCLK

ACK

Data Out Valid

REQ

t

rs

t

pa

t

pdo

t

pw

t

pc

t

doh

t

rh

t

ah