Pattern i/o, Change detection, Triggers start and stop triggers – National Instruments 653X User Manual

Page 94: Rtsi triggers (pci, pxi, at), Bus interfaces

Advertising
background image

Appendix A

Specifications

© National Instruments Corporation

A-3

653X User Manual

Pattern I/O

Direction................................................. Input or output

Maximum sample rate (internally
timed, for small transfers

1

)..................... 20 MHz

Minimum sample rate
(internal clock rate) ................................ 1 S/10 min.

Change Detection

Change-detection resolution .................. 150 ns

Triggers

Start and Stop Triggers

Compatibility ......................................... TTL/CMOS

Trigger types .......................................... Rising or falling edge,

or digital pattern

Pulse width for edge triggers (min.)....... 10 ns

Pattern trigger detection
capabilities ............................................. Detect pattern match or mismatch

on user-selected data lines

Pattern trigger resolution........................ 60 ns or one REQ period,

depending on pattern I/O mode

RTSI Triggers (PCI, PXI, AT)

Trigger lines ........................................... 7

Bus Interfaces

PCI-DIO-32HS/PXI-6533/
PCI-6534/PXI-6534/
AT-DIO-32HS type................................ AT slave with dual DMA

DAQCard-6533 for PCMCIA type ........ PCMCIA slave

1

Small transfer size is the size of the FIFO.