Figure 3-37. long pulse output timing diagram – National Instruments 653X User Manual

Page 91

Advertising
background image

Chapter 3

Timing Diagrams

653X User Manual

3-40

ni.com

Figure 3-37. Long Pulse Output Timing Diagram

Note

With REQ edge latching disabled (default), output data valid will hold t

rdo

ns after

the REQ edge with REQ edge latching enabled, that data will be held for at most t

rdo

ns

after the REQ edge deasserts.

Parameter

Description

Minimum

Maximum

Input Parameters

t

rr*

REQ pulse width

75

t

r*r

REQ inactive duration

75

t

ar

ACK to next REQ

0

Output Parameters

t

aa*

ACK pulse width

125

1

t

r*do

REQ inactive to new output data
(with REQ-edge latching)

0

50

t

rdo

REQ to new output data
(with REQ-edge latching disabled)

0

t

doa

Output data valid to ACK
(with REQ-edge latching disabled)

25

1

t

aa*

(min.)

= 125 + programmable delay

REQ

Output Data Valid

(REQ-edge

latching)

Output Data Valid

(REQ-edge

latching disabled)

t

r*r

t

r*do

t

doa

t

ar

t

aa*

t

rr*

ACK

t

rdo

ACK and REQ are shown as active high