Figure 3-28. leading edge input timing diagram – National Instruments 653X User Manual

Page 82

Advertising
background image

Chapter 3

Timing Diagrams

© National Instruments Corporation

3-31

653X User Manual

Figure 3-28. Leading Edge Input Timing Diagram

Parameter

Description

Minimum

Maximum

Input Parameters

t

rr*

REQ pulse width

75

t

r*r

REQ inactive duration

75

t

ar

ACK to next REQ

0

t

dir(1)

Input data setup to REQ active
(with REQ-edge latching)

0

t

rdi

Input data hold from REQ active
(with REQ-edge latching)

10

t

dir(2)

Input data setup to REQ
(with REQ-edge latching disabled)

0

t

adi

Input data hold from ACK
(with REQ-edge latching disabled)

0

Output Parameters

t

aa*

ACK pulse width

125

t

r*a*

REQ inactive to ACK inactive

150

All timing values are in nanoseconds.

REQ

Input Data Valid

(REQ-edge

latching disabled)

t

r*r

t

r*a*

t

dir(2)

t

adi

t

ar

t

aa*

t

rr*

ACK

Input Data Valid

(REQ-edge

latching)

t

rdi

t

dir(1)

ACK and REQ are shown as active high

Advertising