Viewing system status

Step

Action

1

From the NetLink OAI System screen, select the System Status
Menu
option.

2

At the Systems Status Menu screen, select from the following
options:

Application ActiveYes appears if the application is
communicating correctly with the WLAN Application Gateway
2246. No appears if the application is not connected. This field
is read-only and changes dynamically.

Error Status—The only application-specific error is No ECP
heartbeat
, which means the application failed to send a
heartbeat to the WLAN Application Gateway 2246.

Network Status—information about the connection to the LAN.
See

"Network status" (page 165)

.

Software Versions—lists the software versions currently
running on the WLAN Application Gateway 2246. See

"Software

versions" (page 166)

.

* Telephone Line Status—provides information about the
functioning of each wireless handset registered to the WLAN
Application Gateway 2246. See

"Telephone line status" (page

167)

.

—End—

Network status

The WLAN Application Gateway 2246 is connected to the Ethernet network,
referred to as the LAN. The information about this connection displayed on
the Network Status screen.

The following information appears at the top of the screen:

Ethernet Address—MAC address of the WLAN Application Gateway
2246 (hexadecimal).

Stats Time Period—the length of time the statistics are accumulating
in the Pkts and Bytes columns. This is either the system uptime, or
the time that has elapsed since a user pressed C=Clear while viewing
this display.