Hardware overview

NN47928-302

NN47928-302

The following table provides descriptions of the components of the BSG8ew/12ew/aw/tw
faceplates.

Component

Bsg8 ew or BSG
12ew/tw/aw

Description

Power and system LEDs

Both

show the power and system status

Power Over Ethernet (PoE)

LEDs

BSG12ew/aw/tw only indicate that the associated port is receiving power. There is

one PoE LED for each LAN port.

Link/acc status LEDs

Indicate the activity and status of the LAN port. The LED

becomes active when you connect an Ethernet cable to the

corresponding LAN port.

Power connector

Both

The BSG8ew uses a 12 V DC power adaptor connected with

a faceplate barrel connector.
The BSG12ew/aw/tw use a 48 V DC rear faceplate connected

with a 4-pin DIN connector.

Retention clip mounting hole

BSG8ew only

A small hole into which you insert the power retention clip.

The retention clip secures the power connector to the unit. For

BSG12, the 4-pin DIN connector has self-retention

mechanical design.

Reset system

On the BSG8ew, the system is reset using an external reset

button.
The board is designed to offer an external physical reset

button from the faceplate as a pin-hole access. The reset

asserted for less than 5 seconds activates a general digital

board reset without affecting system parameters stored in

FLASH memory. The reset asserted for more than 5 seconds

activates a total system revert to factory default parameters.

In this scenario, all provision and configured data in persistent

memory (FLASH) is lost and factory defaults values are

restored.
If one of the sub-systems fails during reset, a syslog is

generated and stored in FLASH. The log contains the ID of

the failed subsystem.
On the BSG12ew/aw/tw, the system is reset using an

hardware reset to factory. The hardware reset is performed by

connecting a serial console cable to console port faceplate.

The standard console cable is provided out of box shipping. In

the process, user needs to reset the BSG 12 in to factory

defaults. Connect to the console cable to pc which is not

protected and use the following CLI command.
bsg# system set factory default
bsg# reload
This will reboot BSG 12 with factory default settings.

FE LAN ports

On the BSG8ew, seven FE LAN ports are used to connect to

the LAN.
The BSG12tw and BSG12aw have twelve PoE enabled FE

LAN ports to connect to the LAN.
The BSG12ew has eleven PoE enabled FE LAN ports to

connect to the LAN.

GigE LAN port

On the BSG8ew, one gigabite ethernet (GigE) LAN port

supports data transfer rates of up to 1 000 Mbit/s.