2 Installing the Equipment

2.1 Introduction

2.1.1 Read this first!

The ASI-IP-GTW must be handled carefully and thoughtfully to prevent
safety hazards and damage. Ensure that the personnel designated to
install the unit have the appropriate skills and knowledge.
Follow the instructions for installation and only use installation
accessories recommended by the manufacturer.

2.1.2 To inspect package content

o

Inspect the shipping container for damage. If your shipping
container is damaged, keep the shipping container or cushioning
material until you have inspected the contents of the shipment for
completeness and have checked that the ASI-IP-GTW

mechanically and electrically.

o

Verify that you received the following items and any optional

accessories you may have ordered:

2.2 Installing the Equipment

2.2.1 Selecting a site for the equipment

The ASI-IP-GTW should not be placed where it will be a subject to
extreme temperatures, humidity, or electromagnetic interference.
Specifically, the site you select should meet the following requirements:

o

The ambient temperature should be between 0 to 50 degrees

Celsius (32 and 122 degrees Fahrenheit).

o

The relative humidity should be less than 90 percent, non-
condensing. Do not install the unit in areas of high humidity or

where there is danger of water ingress.

o

Surrounding electrical devices should not exceed the
electromagnetic field (RFC) standards for IEC 801-3, Level 2

(3V/M) field strength.

o

Make sure that the equipment receives adequate ventilation. Do

not block the ventilation holes on each side of the ASI-IP-GTW.

o

The power outlet should be within 1.8 meters (6 feet) of the ASI-IP-

GTW.

o

ASI to IP Gateway

o

Power cord

o

User’s manual

Note: 48V DC versions do not ship with a power cord, but a male
Power D-SUB connector for soldering to the supply leads.