85

Limits for the harmonic current
emission.

EN 50082-1

European

Generic Immunity Standard Part 1:
Domestic, commercial and light
industry environment.

FCC

US

Conducted and radiated emission
limits for a Class A digital device,
pursuant to the Code of Federal
Regulations (CFR) Title 47-
Telecommunications, Part 15: radio
frequency devices, subpart B –
Unintentional Radiators.

8.9.3 CE Marking

The CE mark is affixed to indicate compliance with the following
directives:

o

89/336/EEC of 3 May 1989 on the approximation of the laws of
the Member States relating to electromagnetic compatibility.

o

73/23/EEC of 19 February 1973 on the harmonisation of the laws
of the Member States relating to electrical equipment designed for

the use within certain voltage limits.

o

1999/5/EC of March 1999 on radio equipment and
telecommunication terminal equipment and the mutual

recognition of their conformity.

o

8.9.4 Interface to “public telecommunication system”

The equipment is not constructed for electrical connection directly to a
"public telecommunication system". None of the signals shall be
connected directly from the unit to a "public telecommunication
system" leaving the building without using some kind of interface in
between such as a telecom terminal, switch or similar unit. Such kind
of buffer is required to achieve a protective electrical barrier between
the "public telecommunication system" and the unit. This electrical
barrier is required to achieve protection against lightening or faults in
nearby electrical installations.