10 ethernet data port, 11 power supply, 12 management port – Network Technologies DVB-ASI to IP User Manual

Page 18: 13 technical earth, 14 alarm, 3 power, 1 ac power supply, 2 power cable and protective earth, 15 general, Power

Advertising
background image

ASI-IP-GTW User's Manual

Page

18

have ordered the unit with less than 4 ASI ports, the enabled ports
starts at number 1 up to the number of ports ordered.
In IP bi-directional mode, half the DVB-ASI connectors are used as
inputs, and the other half as DVB-ASI outputs. ASI connectors 1, 2, 5
and 6 are used as inputs, while ASI connectors 3, 4, 7 and 8 are used
as outputs.

1.1.1.10 Ethernet data port
Connect the Ethernet data port to the network. In IP transmit mode,
the ASI-IP-GTW will send an IP stream to the network. In IP receive
mode, the ASI-IP-GTW will receive an IP stream from the network.

1.1.1.11 Power supply
Section 2.3 provides details of the power supply, protective earth and
security. Read all these instructions, prior to connecting the unit to
power mains.

1.1.1.12 Management port
The ASI-IP-GTW provides one Ethernet port for control and
management. Connect the management port to the management
network.

1.1.1.13 Technical Earth
Connect the Technical earth to a suitable earth point.

1.1.1.14 Alarm
The ASI-IP-GTW provides an alarm relay for connection to external
alarm system.

2.3 Power

2.3.1 AC Power Supply

The ASI-IP-GTW provides a wide-ranging power supply covering a rate
voltage range 100-240Vac, 50/60Hz. Please refer to

Appendix B: Technical Specification for a detailed specification of the
AC power supply.

2.3.2 Power Cable and Protective Earth

1.1.1.15 General
Ensure that the AC power cable is suitable for the country in which the
unit is to be operated.

Warning: This product should be operated only from the type of power
source indicated on the marking label. Please consult a qualified
electrical engineer or your local power company if you are not sure of
the power supply to your business.