Manual Update: Enter the wanted date and time and press this button
to set the clock manually. Remark that if you are running in SNTP
mode and the device receives answers from the time server, the time
value will be overwritten. The manual update button only updates the
clock value, to configure time zone, clock source and SNTP server
address you have to press the Apply button at the main tool bar.

3.5.3 Alarms

The alarm page contains a list of all alarm events that can be displayed
by the unit.

Figure 12. Alarm sub-page

In order to change the severity level of an alarm event, select the alarm
event in the left table and the selected event will appear in the "Filter
Settings" frame. Select the severity level (Filtered, Warning or Critical)
from the list and press "Apply Filter Change" to change the severity
level. The severity level is reflected in the user interface and in the
SNMP traps sent by the unit.
The default severity level is shown in the "Default sev." column and the
current severity level if different from default is shown in the
"Overridden sev." column.

3.5.4 SNMP

The SNMP page allows configuration of the SNMP Trap Servers that the
unit should send SNMP traps to.